Infant Transport Incubator MGE-BN4DT

  • Two temperature control modes
  • Separate display
  • Temperature set function
  • Humidity control
  • Oxygen supply
  • Alarm indications
  • Side door
  • Adjustable height
  • Observation lamp
  • Power supply
Fill out my online form.
Share:​
Table of Contents

Description

Infant Transport Incubator MGE-BN4DT

  • Two temperature control modes
  • Separate display
  • Temperature set function
  • Humidity control
  • Oxygen supply
  • Alarm indications
  • Side door
  • Adjustable height
  • Observation lamp
  • Power supply
transportable incubator bn4dt

Specification

  • AC power requirement: AC110-230V/50-60Hz, 400VA
  • DC Power requirement: DC12V/10A or DC24V/6A
  • Control Mode: Air mode and Baby mode controlled by microcomputer
  • Air temperature control range: 25°C-37°C(Override mode 37°C-38°C)
  • Baby temperature control range: 34°C-37°C (Override mode 37-37.5°C)
  • Skin temperature sensor accuracy: # 0.2°C
  • The temperature fluctuation range between incubator temper
  • -ature and average incubator temperature (under stable temper
  • -ature condition): €1.0°C
  • Temperature uniformity: €1.5°C (mattress is on the horizontal position)
  • Noise inside hood: ≤52 dB(A)
  • Failure alarm: over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm and so on.
  • Battery continuous working time: 90min (Set temperature is 36°C-
  • Ambient temperature is 15°C)

Brief Introduction​

  • Two temperature control modes: Air mode and Baby mode controlled by micro-computer;
  • Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance;
  • Set temperature, Air temperature, Baby temperature and Internal battery capacity can be displayed separately;
  • Multiple failure alarm indications;
  • “>37°C” temperature set function as optional configuration;
  • Double wall acrylic glass hood with side door so that the bassinet can be pulled out from it;
  • Passive humidification;
    The height of whole unit can be adjusted;
  • Oxygen supply system;
  • Observation lamp.

Standard Configuration

Main body (Including the Hood, Controller, Bassinet, Internal battery. and Observation Lamp). Oxygen cylinders. Oxygen supply system, Skin temperature sensor, I.V. Pole, Mattress, Adjustable stand).

Environmental temperature

Operating range: 10°C-30°C (Set temperature should be
3°C higher than the environment temperature)
Ambient air velocity: >0.3 m/s, < 1.0m/s

Optional Configuration

“>37°” override temperature mode,

Disposable skin temperature sensor,

Ambulance trolley.

Product Packaging

  • Package: Main body and Cabinet are packed into two cartons
  • Dimension (Main body): 1090mm × 655mm x 760mm
    (Cabinet): 1380mm x 610mm × 400mm
  • Gross Weight (Main body): 80Kg
    (Cabinet): 53Kg